Let EcoTreck take the headache and stress out of the equation.
EcoTrecks staff is made up from a diverse group of professionals from prior insurance adjusters, HVAC professionals , commercial and residential contractors and remediation professionals. Our staff is trained through the IICRC and IRI institute, Surviving Mold Conferences, and is always looking for the most up to date training and procedures. Ecotreck specializes in remediation for clients with CIRS and Environmentally Acquired Illness.
Let EcoTreck take the headache and stress out of the equation.
Third party Mold Testing and Protocol
Free Mold Inspections
Green Remediation Products
Small particulate cleaning
Wet and dry wiping
Antimicrobial Sealing
Hepa Air Scrubbing and Vacuuming
Third Party Asbestos Testing
Attic Remediation
Moisture Testing
Crawlspace Vapor Barriers
Troubleshooting
Moisture Testing
Containment
Mold Removal Quotes
Kevin Welu
Kevin R Welu has been in the building industry for over 29 years, Steamboat Springs resident since 2008.
Prior to his time in Colorado, he was a Hurricane Katrina and Hurricane Rita catastrophe adjuster. Kevin is a certified , covid19 and Pandemic Preparedness High Performance Cleaning through the 2020 CIRI Science Symposium ,Casualty and Surety adjusting, wind and water damage, storm water management, erosion control, , 10 OSHA safety and health outreach training and State Farm wind, hail, , IICRC certified water . IRI mold remediation specialists. Completed Greg Weatherman Advanced Small Particle Remediation Workshop at 2019 Mold Congress. 24 hr Radon mitigation course Midwest Radon Consortium. ECI certified Crawlspace Encapsulation Shield, Drain System Shield, concrete Shield, Crack injection.
The following are statements from the EPA. For more information please visit EPA.gov
Lung cancer kills thousands of Americans every year. Smoking, radon, and secondhand smoke are the leading causes of lung cancer.
Smoking is the leading cause of lung cancer. Smoking causes an estimated 160,000* cancer deaths in the U.S. every year (American Cancer Society, 2004).
Radon is the number one cause of lung cancer among non-smokers, according to EPA estimates. Overall, radon is the second leading cause of lung cancer. Radon is responsible for about 21,000 lung cancer deaths every year. About 2,900 of these deaths occur among people who have never smoked.
Secondhand smoke is the third leading cause of lung cancer and responsible for an estimated 3,000 lung cancer deaths every year.
Types of Radon Mitigation
Radon levels are measured in picocuries per liter, or pCi/L. Levels of 4 pCi/L or higher are considered hazardous. Radon levels less than 4 pCi/L still pose a risk and in many cases can be reduced, although it is difficult to reduce levels below 2 pCi/L.
Mitigation Strategies
The most common mitigation strategy involves soil depressurization which works by reversing the air pressure relationship between indoors and the soil reducing concentration in the soil adjacent to the indoors.
Types: Active soil depressurization (a fan is used to depressurize). And passive soil depressurization (a soil gas retarder between the gas permeable layer and slab or over exposed soils in the crawlspace.
Types of ASD: A slab on grade would use a sub slab depressurization system and a crawlspace would use a submembrane depressurization. ( please refer to our crawlspace liner system tab for this system).
Radon mitigation (EPA.gov)
Basement and Slab-on-Grade Homes In homes that have a basement or a slab-on-grade foundation, radon is usually reduced by one of four types of soil suction: subslab suction, drain-tile suction, sump-hole suction, or block-wall suction. Active subslab suction – also called subslab depressurization – is the most common and usually the most reliable radon reduction method. One or more suction pipes are inserted through the floor slab into the crushed rock or soil underneath. They also may be inserted below the concrete slab from outside the home. The number and location of suction pipes that are needed depends on how easily air can move in the crushed rock or soil under the slab and on the strength of the radon source. Often, only a single suction point is needed.
Crawlspace-Homes. An effective method to reduce radon levels in crawlspace homes involves covering the earth floor with a high-density plastic sheet. A vent pipe and fan are used to draw the radon from under the sheet and vent it to the outdoors. This form of soil suction is called submembrane suction, and when properly applied is the most effective way to reduce radon levels in crawlspace homes.
Another less-favorable option is active crawlspace depressurization, which involves drawing air directly from the crawlspace using a fan. This technique generally does not work as well as submembrane suction and requires special attention to combustion appliance back-drafting and sealing the crawlspace from other portions of the home. It also may result in increased energy costs due to loss of conditioned air from the home. In some cases, radon levels can be lowered by ventilating the crawlspace passively, or actively, with the use of a fan. Crawlspace ventilation may lower indoor radon levels both by reducing the home’s suction on the soil and by diluting the radon beneath the home. Passive ventilation in a crawlspace is <href=”https: www.epa.gov=”” radon”=””>www.epa.gov/radon 11 achieved by opening vents or installing additional vents. Active ventilation uses a fan to blow air through the crawlspace instead of relying on natural air circulation. In colder climates, for either passive or active crawlspace ventilation, water pipes, sewer lines and appliances in the crawlspace may need to be insulated against the cold. These ventilation options could result in increased energy costs for the home.</href=”https:>